My worst experience testing transducers and operating them


0

Transformer operation reliable and safe electrical power delivery relies on transducer reliability which is greatly enhanced with audio test plans. These test plans should be prepared by both manufacturers and end users to develop comprehensive and effective plans and specifications. The plan and specification developers must take into account several factors such as expected environmental conditions, types of grounding, exposure to lightning, and altered transient conditions. My worst experience in testing and operating transducers (and how I fixed things) The nominal rating specifications are not the only specifications that should be included, but also special classifications such as impedance, volume or otherwise in the test plan and their wording in the specifications should be taken into account. It is imperative to define the correct set of test plans and test levels specifications to suit a transformer application in order to have a reliable overall power system. Transformers undergo a number of test schemes in order to achieve: Compliance with User Specifications Quality and Reliability Assessment Verification of Design Calculation Compliance with applicable industry standards This technical article discusses a comprehensive approach to successfully commissioned transformers. The set of criteria used, test categories, and test sequences must be determined in advance. The pre-commissioning phase is vital in finding any issues before engaging in the commissioning process, and delays during the commissioning phase are expected for many reasons, but this can be greatly enhanced by imposing a systematic procedure. Moreover, a few case studies were discussed briefly to highlight some common problems that would likely be encountered during commissioning, and some of these cases could have been avoided by following a simple visual inspection, so it could not be overemphasized to follow the following – a written procedure schedule Contents: ANSI standards for transducers Classification of tests Test sequence Transformer operation before commissioning: Sweep frequency response analysis (SFRA) Dielectric response frequency (DFR) Transformer case studies related to differential protection Oil and insulators analysis Oil level problem Problems in the differential protection reward of transformers – Standards used for transformers Power (PDF) 1. ANSI Standards for Power Transformers The ANSI standards for transducers are provided in the C57 Series of Standards. Power transformers, in addition to the general requirements for distribution transformers, are presented in the following two standards: IEEE C57.12.00: IEEE Standard General Requirements for Flooded Distribution, Power, and Regulation of Transformers IEEE C57.12.90: IEEE Standard Test Code for Liquid – Distribution, Power and Immersed Regulation Transformers; And ANSI Distribution and Transformer Short Circuit Test Manual There are many other standards in the ANSI C57 Series of transformers that cover specific products and special applications. It also includes guides, recommended practices, and tutorials. Indeed, these documents are of great interest to readers who need detailed information on testing and distribution of power transformers. The above standards are very important references because they act as an effective means of communication between manufacturers and users. They identify important features, provide minimum requirements for safe and reliable operation, and serve as valuable references for technical information. Via Twitter) Refer to Table of Contents ↑ 2. Classification of tests Transformer tests are classified according to ANSI and IEEE standards in routine tests, design tests, and other tests. Further testing is applied to ensure transformer quality standards throughout the transformer production cycle. Transformer test classes are listed in Table 1 – Table 1 – Transformer test classes No – Transients – 1 Lightning pulse: – full wave – cut wave – steep wave 2 switching pulse low frequency number (power) 1 applied voltage 2 induced phase One 3 Three-phase inductor 4 Partial discharge number Performance tests Characteristics 1 No load loss 2 Excitation current% 3 Load loss 4 Resistance% 5 Zero series resistance 6 Ratio test 7 Short circuit test Thermal test number 1 Winding resistance 2 Heat run test: – High Oil – winding height – hottest point height 3 Increase in heat load 4 Gas in oil 5 Thermal test number 1 Other transformer test – Level tests 310 kV Megger4 excitation current ground core 5 Electrical center 6 Current increase 7 Dew point 8 Basic loss before pulse 9 Control Circuit Test 10 Test on Series Transformer 11 LTC Tests 12 Initial Ratio Tests 13 Oil Conservation System CT14 Bushing Test The stage at which these tests are performed varies; Some tests are performed before the core and coil are assembled inside the tank, and some tests are done after the transformer is fully assembled and made ready for final testing. This final test term is not really a final test, as additional testing is carried out directly prior to shipment along with commissioning tests at customer sites. In all of these tests, the test levels and acceptance / rejection criteria are of the utmost importance in the test plan jointly developed between the manufacturer and the switch customer. Get access to all premium HV / MV / LV technical articles, electrical engineering guides, and papers. Check the benefits of each plan and choose the membership plan that works best for you or your organization. You can choose the Plus, Pro, or Enterprise membership plan on a yearly basis. SPECIAL OFFER – Get 15% off PRO Premium plan, use discount code: login


Like it? Share with your friends!

0

What's Your Reaction?

hate hate
0
hate
confused confused
0
confused
fail fail
0
fail
fun fun
0
fun
geeky geeky
0
geeky
love love
0
love
lol lol
0
lol
omg omg
0
omg
win win
0
win
Joseph

0 Comments

Your email address will not be published. Required fields are marked *